Aluminium/Copper ConductorXLPE Power Cable IEC 60502

Nominal Voltage: Up to 35kv
Certificate: ISO 9001
Supply Ability: 3000km/Month
Packaging Details: Wood-metal Drum or Metal Drum.
Port: Qingdao / Tianjin/ Ningbo / Shanghai

Product Details

Aluminum /Copper Conductor XLPE Power Cable IEC 60502


Product Application
The products applies to transmission and distribution of high voltage power lines at rated voltage 6-35kv, the max rated temperature of conductor is 90℃, when short circuited (Max period is not exceed 5s), the max temperature is 250℃


Product Structure
Up to 35kv Power Cable Consists of Aluminum or Copper Core, XLPE Insulation, Wrapping tape, Inner Sheath, Metal armor, PVC Sheath.
The commonly known types, Aluminium Conductor Xlpe Power Cable, Copper /Xlpe /Swa/Pvc Power Cable.


Product Property
The rated voltage mainly consists of 3.6/6kv, 6/10kv, 8.7/15kv, 12/20kv, 18/30kv, Metal armor: Aluminum/Steel wire/tape armor or unarmored, flame retardant.


Technical Data

3.6/6kV 1 Core XLPE Cable

Construction Table (in accordance with IEC 60502-2,61034 and 60754)

Nominal Cross-section Area

Approx. Outside diameter of Conductor

Thickness of Insulation (nom.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire(nom.)

Thickness of PVC Outer Sheath (nom.)

Approx.Overall Diameter

Approx.Weight of Cable

Copper Conductor

Aluminium Conductor

AWA

DATA

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

mm²

mm

mm

mm

mm

mm

mm

kg/km

kg/km

10

4.05

2.5

1.2

1.2

0.9

0.5

1.4

1.8

1.8

15

21

1.9

320

550

480

 

16

4.7

2.5

1.2

1.2

0.9

0.5

1.4

1.8

1.8

16

21

20

390

630

550

290

530

450

25

5.9

2.5

1.2

1.2

1.6

0.5

1.5

1.8

1.8

18

24

21

500

850

670

350

700

510

35

6.9

2.5

1.2

1.2

1.6

0.5

1.5

1.8

1.8

19

25

22

610

980

790

400

760

570

50

8.1

2.5

1.2

1.2

1.6

0.5

1.6

1.8

1.8

20

26

23

760

1,140

940

470

850

640

70

9.8

2.5

1.2

1.2

1.6

0.5

1.6

1.8

1.8

22

28

25

990

1,400

1,180

560

970

750

95

11.4

2.5

1.2

1.2

1.6

0.5

1.7

1.9

1.8

24

30

27

1,280

1,710

1,460

690

1,130

880

120

12.8

2.5

1.2

1.2

1.6

0.5

1.7

1.9

1.8

25

31

28

1,540

2,010

1,740

790

1,260

990

150

14.2

2.5

1.2

1.2

1.6

0.5

1.8

2.0

1.9

27

33

30

1,840

2,330

2,050

910

1,400

1,120

185

15.8

2.5

1.2

1.2

2.0

0.5

1.8

2.0

1.9

28

35

31

2,220

2,830

2,440

1,060

1,670

1,280

240

18.1

2.6

1.2

1.2

2.0

0.5

1.9

2.1

2.0

32

39

35

2,870

3,540

3,120

1,330

2,000

1,580

300

20.4

2.8

1.2

1.2

2.0

0.5

2.0

2.2

2.1

35

41

39

3,530

4,250

3,950

1,600

2,320

2,010

400

23.2

3.0

1.2

1.2

2.0

0.5

2.1

2.3

2.3

38

45

42

4,420

5,220

4,890

1,950

2,750

2,430

500

26.3

3.2

1.3

1.3

2.5

0.5

2.2

2.5

2.4

42

50

46

5,560

6,640

6,400

2,400

3,480

2,930

630

30.2

3.2

1.4

 

2.5

 

2.3

2.6

 

47

55

 

7,020

7,920

 

2,920

4,130

 

800

34.0

3.2

1.4

 

2.5

 

2.4

2.7

 

50

59

 

8,900

9,780

 

3,640

4,860

 

1,000

38.7

3.2

1.6

 

2.5

 

2.6

2.9

 

55

64

 

11,010

12,220

 

4,120

5,720

 

16mm² to 800mm² are normal compact round for single and multi core cable.
800mm² and above are compact round segments for single core cable.
AWA:Aluminium Wire Armoured / DATA:Double Al.Tape Armoured / UnAr.:Unamoured
Only the halogen free cables shall be generally complied with IEC 61034and 60754.
For the 1 core cables armoured with magnetic materials using in communication system , even specific strcuture is applied,
the carrying capacity will be greatly reduced, so should be should be carefully selected.


3.6/6kV 3 Cores XLPE Cable

Construction Table (in accordance with IEC 60502-2,61034 and 60754)

Nominal Cross-section Area

Approx. Outside diameter of Conductor

Thickness of Insulation (nom.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire(nom.)

Thickness of PVC Outer Sheath (nom.)

Approx. Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluminium Conductor

GSWA

DATA

GSWA

DATA

UnAr

GSWA

DATA

UnAr

GSWA

DATA

UnAr

GSWA

DATA

UnAr

GSWA

DATA

mm²

mm

mm

mm

mm

mm

mm

kg/km

kg/km

10

4.05

2.5

1.2

1.2

2.0

0.2

1.9

2.1

2.0

30

37

33

1,040

2,440

1,420

 

16

4.7

2.5

1.2

1.2

2.0

0.5

2.0

2.2

2.1

31

38

36

1,270

2,730

2,040

970

2,440

1,740

25

5.9

2.5

1.2

1.2

2.0

0.5

2.0

2.3

2.2

34

41

38

1,610

3,220

2,470

1,140

2,750

2,010

35

6.9

2.5

1.2

1.2

2.0

0.5

2.1

2.4

2.3

37

44

41

1,990

3,690

2,900

1,330

3,040

2,250

50

8.1

2.5

1.3

1.3

2.5

0.5

2.2

2.5

2.4

39

47

44

2,460

4,730

3,460

1,570

3,840

2,570

70

9.8

2.5

1.4

1.4

2.5

0.5

2.3

2.6

2.5

43

52

48

3,200

5,730

4,320

1,910

4,440

3,030

95

11.4

2.5

1.4

1.4

2.5

0.5

2.5

2.7

2.6

47

56

52

4,140

6,840

5,330

2,350

5,050

3,540

120

12.8

2.5

1.5

1.5

2.5

0.5

2.6

2.9

2.8

51

59

56

5,030

7,980

6,350

2,750

5,710

4,080

150

14.2

2.5

1.6

1.6

2.5

0.5

2.7

3.0

2.9

54

63

59

5,960

9,140

7,400

3,150

6,330

4,590

185

15.8

2.5

1.6

1.6

2.5

0.5

2.8

3.1

3.0

58

67

63

7,190

10,570

8,720

3,680

7,060

5,210

240

18.1

2.6

1.7

1.7

2.5

0.5

3.0

3.3

3.2

65

74

70

9,310

13,150

11,050

4,650

8,490

6,390

300

20.4

2.8

1.8

1.8

3.15

0.5

3.2

3.5

3.4

71

82

76

11,460

16,680

13,390

5,600

10,820

7,530

400

23.2

3.0

2.0

2.0

3.15

0.8

3.4

3.8

3.7

78

89

85

14,330

21,021

17,510

6,850

12,730

10,090

16mm² to 800mm² are normal compact round for single and multi core cable.
800mm² and above are compact round segments for single core cable.
GSWA:Galvanized Steel Wire Armoured/ DSTA:Double Steel Tape Armoured/ UnAr:Unarmoured
Only the halogen free cables shall be generally complied with IEC 61034and 60754.

6/10kV 1 Core XLPE Cable

Construction Table (in accordance with IEC 60502-2,61034 and 60754)

Nominal Cross-section Area

Approx. Outside diameter of Conductor

Thickness of Insulation (nom.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire(nom.)

Thickness of PVC Outer Sheath (nom.)

Approx.Overall Diameter

Approx.Weight of Cable

Copper Conductor

Aluminium Conductor

AWA

DATA

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

mm²

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

3.4

1.2

1.2

1.6

0.5

1.5

1.8

1.8

19

24

22

460

800

630

360

710

530

25

5.9

3.4

1.2

1.2

1.6

0.5

1.5

1.8

1.8

20

26

23

570

940

760

420

790

600

35

6.9

3.4

1.2

1.2

1.6

0.5

1.6

1.8

1.8

21

27

24

700

1,070

880

480

860

670

50

8.1

3.4

1.2

1.2

1.6

0.5

1.6

1.8

1.8

22

28

25

840

1,230

1,030

550

940

740

70

9.8

3.4

1.2

1.2

1.6

0.5

1.7

1.9

1.8

24

30

27

1,090

1,500

1,280

660

1,080

850

95

11.4

3.4

1.2

1.2

1.6

0.5

1.7

1.9

1.8

24

31

29

1,370

1,810

1,570

780

1,230

980

120

12.8

3.4

1.2

1.2

1.6

0.5

1.8

2.0

1.9

27

33

31

1,650

2,130

1,870

900

1,380

1,120

150

14.2

3.4

1.2

1.2

2.0

0.5

1.8

2.0

1.9

29

35

32

1,940

2,520

2,170

1,020

1,600

1,240

185

15.8

3.4

1.2

1.2

2.0

0.5

1.9

2.1

2.0

31

37

34

2,340

2,960

2,580

1,180

1,800

1,420

240

18.1

3.4

1.2

1.2

2.0

0.5

2.0

2.2

2.1

34

40

37

2,990

3,660

3,260

1,450

2,120

1,720

300

20.4

3.4

1.2

1.2

2.0

0.5

2.0

2.3

2.2

36

43

40

3,620

4,350

4,070

2,530

2,410

2,140

400

23.2

3.4

1.2

1.2

2.00

0.5

2.1

2.4

2.3

39

46

43

4,490

5,280

4,970

2,020

2,810

2,510

500

26.3

3.4

1.3

1.3

2.50

0.5

2.2

2.5

2.4

42

50

47

5,610

6,650

6,160

2,440

3,480

2,990

630

30.2

3.4

1.4

 

2.5

 

2.3

2.6

 

47

55

 

7,170

7,950

 

3,070

4,160

 

800

34

3.4

1.4

 

2.5

 

2.5

2.7

 

51

59

 

8,980

9,800

 

3,720

4,880

 

1,000

38.7

3.4

1.6

 

2.5

 

2.6

2.9

 

52

65

 

11,060

12,230

 

4,480

5,730

 

16mm² to 800mm² are normal compact round for single and multi core cable.
800mm² and above are compact round segments for single core cable.
AWA:Aluminium Wire Armoured / DATA:Double Al.Tape Armoured / UnAr.:Unamoured
Only the halogen free cables shall be generally complied with IEC 61034and 60754.
For the 1 core cables armoured with magnetic materials using in communication system , even specific strcuture is applied,
the carrying capacity will be greatly reduced, so should be should be carefully selected.

6/10kV 3 Cores XLPE Cable

Construction Table (in accordance with IEC 60502-2,61034 and 60754)

Nominal Cross-section Area

Approx. Outside diameter of Conductor

Thickness of Insulation (nom.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire(nom.)

Thickness of PVC Outer Sheath (nom.)

Approx.Overall Diameter

Approx.Weight of Cable

Copper Conductor

Aluminium Conductor

GSWA

DATA

GSWA

DATA

UnAr

GSWA

DATA

UnAr

GSWA

DATA

UnAr

GSWA

DATA

UnAr

GSWA

DATA

mm²

mm

mm

mm

mm

mm

mm

kg/km

kg/km

16

4.7

3.4

1.2

1.2

2.0

0.5

2.1

2.3

2.3

36

43

41

1,520

3,150

2,440

1,230

2,860

2,140

25

5.9

3.4

1.3

1.3

2.5

0.5

2.2

2.5

2.3

39

47

44

1,920

4,140

2,900

1,450

3,670

2,430

35

6.9

3.4

1.3

1.3

2.5

0.5

2.3

2.5

2.4

42

49

46

2,310

4,640

3,350

1,660

3,990

2,690

50

8.1

3.4

1.4

1.4

2.5

0.5

2.4

2.6

2.5

44

52

49

2,800

5,280

3,920

1,900

4,390

3,030

70

9.8

3.4

1.4

1.4

2.5

0.5

2.5

2.8

2.7

48

56

53

3,580

6,290

4,820

2,290

5,010

3,540

95

11.4

3.4

1.5

1.5

2.5

0.5

2.6

2.9

2.8

52

60

57

4,510

7,480

5,090

2,730

5,700

4,090

120

12.8

3.4

1.6

1.6

2.5

0.5

2.7

3.0

2.9

56

64

61

5,430

8,610

6,910

1,190

6,330

4,630

150

14.2

3.4

1.6

1.6

2.5

0.5

2.8

3.1

3.0

59

67

64

6,370

9,730

7,930

3,560

6,920

5,110

185

15.8

3.4

1.7

1.7

2.5

0.5

2.9

3.2

3.1

63

71

68

7,640

12,230

9,340

4,130

7,720

5,820

240

18.1

3.4

1.8

1.8

3.15

0.5

3.1

3.4

3.3

70

79

75

9,840

14,770

11,660

5,180

10,110

6,990

300

20.4

3.4

1.9

1.9

3.15

0.5

3.3

3.6

3.5

74

84

80

11,830

17,170

13,890

5,970

11,310

8,030

400

23.2

3.4

2.0

2.0

3.15

0.8

3.5

3.8

3.7

81

92

88

14,650

20,640

17,880

7,170

13,160

10,400

16mm² to 800mm² are normal compact round for single and multi core cable.
800mm² and above are compact round segments for single core cable.
GSWA:Galvanized Steel Wire Armoured/ DSTA:Double Steel Tape Armoured/ UnAr:Unarmoured
Only the halogen free cables shall be generally complied with IEC 61034and 60754.

8.7/15kV 1 Core XLPE Cable

Construction Table (in accordance with IEC 60502-2,61034 and 60754)

Nominal Croess-sectional Area

Approx. Outside diameter of Conductor

Thickness of the insulation (non.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire (nom.)

Thickness of the PVC Outer Sheath (nom.)

Approx. Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluninum Conductor

AWA

DTA

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

mm2

mm

mm

mm

mm

mm

mm

kg/km

kg/km

25

5.9

4.5

1.2

1.2

1.6

0.5

1.6

1.8

1.8

22

28

26

70

1,070

870

520

910

710

35

6.9

4.5

1.2

1.2

1.6

0.5

1.7

1.9

1.8

24

29

27

800

1,210

990

590

1,000

780

50

8.1

4.5

1.2

1.2

1.6

0.5

1.7

1.9

1.8

25

30

28

950

1,380

1,150

660

1,090

860

70

9.8

4.5

1.2

1.2

1.6

0.5

1.7

1.9

1.9

26

32

30

1,190

1,640

1,410

770

1,220

990

95

11.4

4.5

1.2

1.2

2.0

0.5

1.8

2.0

1.9

28

35

31

1,490

2,070

1,720

900

1,480

1,130

120

12.8

4.5

1.2

1.2

2.0

0.5

1.9

2.1

2.0

30

37

33

1,790

2,390

2,020

1,030

1,640

1,270

150

14.2

4.5

1.2

1.2

2.0

0.5

1.9

2.1

2.0

32

38

35

2,080

2,710

2,330

1,150

1,780

1,410

185

15.8

4.5

1.2

1.2

2.0

0.5

2.0

2.2

2.1

33

40

36

2,490

3,150

2,740

1,330

1,990

1,580

240

18.1

4.5

1.2

1.2

2.0

0.5

2.0

2.3

2.2

36

43

41

3,130

3,870

3,590

1,590

2,330

2,050

300

20.4

4.5

1.2

1.2

2.0

0.5

2.1

2.3

2.3

39

45

43

3,790

4,560

4,270

1,850

2,610

2,330

400

23.2

4.5

1.3

1.3

2.5

0.5

2.2

2.5

2.4

43

49

46

4,670

5,690

5,210

2,200

3,220

2,740

500

26.3

4.5

1.3

1.3

2.5

0.5

2.3

2.6

2.5

45

53

50

5,800

6,960

6,380

2,630

3,800

3,210

630

30.2

4.5

1.4

 

2.5

 

2.4

2.6

 

50

58

 

7,390

9,560

 

3,290

5,760

 

800

34

4.5

1.4

 

2.5

 

2.5

2.8

 

54

62

 

9,180

11,560

 

3,930

6,630

 

1000

38.7

4.5

1.6

 

2.5

 

2.7

3.0

 

58

67

 

11,310

14,190

 

4,270

7,700

 




















16mm2 to 800mm2 are normal compact round for single and multi core cable.
800mm2 and above are compact round segments for single core cable.
AWA:Aluminum Wire Armoured /DATA:Double Al.Tape Amoured/UnAr:Unarmoured
Only the galogen free cables shall be generally complied with IEC 61034 and 60754.
For the 1 core cables armoured with magnetic materials using in communication system ,
even specific strcuture is applied, the carrying capacity will be greatly reduced, so should be should be carefully selected.

8.7/15kV 3 Cores XLPE Cable

Construction Table (in accordance with IEC 60502-2, 61034 and 60754)

Nominal Croess-sectional Area

Approx. Outside diameter of Conductor

Thickness of the insulation (non.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire (nom.)

Thickness of the PVC Outer Sheath (nom.)

Approx. Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluninum Conductor

GSWA

DSTA

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

mm2

mm

mm

mm

mm

mm

mm

kg/km

kg/km

25

5.9

4.5

1.4

1.4

2.5

0.5

2.4

2.6

2.5

45

53

49

2,280

4,770

3,420

1,810

4,310

2,950

35

6.9

4.5

1.4

1.4

2.5

0.5

2.4

2.7

2.6

47

55

52

2,680

5,330

3,900

2,030

4,680

3,340

50

8.1

4.5

1.5

1.5

2.5

0.5

2.5

2.8

2.7

50

58

55

3,190

6,020

4,500

2,290

5,120

3,610

70

9.8

4.5

1.5

1.5

2.5

0.5

2.7

2.9

2.8

54

62

59

4,030

7,060

5,410

2,740

5,780

4,120

95

11.4

4.5

1.6

1.6

2.5

0.5

2.8

3.1

3.0

58

66

63

5,000

8,270

6,530

3,210

6,490

4,740

120

12.8

4.5

1.7

1.7

2.5

0.5

2.9

3.2

3.1

61

70

66

5,930

9,430

7,580

3,660

7,150

5,310

150

14.2

4.5

1.7

1.7

3.15

0.5

3.0

3.2

3.2

64

74

70

6,920

11,470

8,650

4,110

8,670

5,840

185

15.8

4.5

1.8

1.8

3.15

0.5

3.1

3.4

3.3

68

78

74

8,190

13,070

10,060

4,680

9,560

6,550

240

18.1

4.5

1.9

1.9

3.15

0.5

3.3

3.6

3.5

75

85

80

10,390

15,800

12,460

5,720

11,140

7,800

300

20.4

4.5

2.0

2.0

3.15

0.8

3.4

3.8

3.7

80

90

87

12,470

18,270

15,720

6,610

12,410

9,860

400

23.2

4.5

2.1

2.1

3.15

0.8

3.6

4.0

3.9

86

95

93

15,330

21,800

18,860

7,850

14,320

11,380

16mm2 to 800mm2 are normal compact round for single and multi core cable.
800mm2 and above are compact round segments for single core cable.
GSWA:Galvanized Wire Armoured /DSTA:Double Steel Tape Amoured/UnAr:Unarmoured
Only the galogen free cables shall be generally complied with IEC 61034 and 60754.

12/20kV 1 Core XLPE Cable

Construction Table(in accordance with IEC 60502-2,61034 and 60754)

Nominal Croess-sectional Area

Approx. Outside diameter of Conductor

Thickness of the insulation (non.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire (nom.)

Thickness of the PVC Outer Sheath (nom.)

Approx. Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluninum Conductor

AWA

DATA

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

UnAr

AWA

DATA

mm2

mm

mm

mm

mm

mm

mm

kg/km

kg/km

35

6.9

5.5

1.2

1.2

1.6

0.5

1.7

1.9

1.8

26

32

29

910

1,370

1,120

700

1,150

910

50

8.1

5.5

1.2

1.2

2

0.5

1.8

2

1.9

28

33

31

1,080

1,550

1,300

790

1,260

1,000

70

9.8

5.5

1.2

1.2

2

0.5

1.8

2

1.9

29

36

32

1,330

1,920

1,560

900

1,490

1,130

95

11.4

5.5

1.2

1.2

2

0.5

1.9

2.1

2

31

38

34

1,640

2,270

1,880

1,050

1,680

1,290

120

12.8

5.5

1.2

1.2

2

0.5

1.9

2.1

2

33

39

36

1,920

2,580

2,180

1,170

1,820

1,430

150

14.2

5.5

1.2

1.2

2

0.5

2

2.2

2.1

34

41

39

2,240

2,920

2,660

1,310

1,990

1,730

185

15.8

5.5

1.2

1.2

2

0.5

2

2.2

2.2

36

42

40

2,640

3,340

3,090

1,480

2,180

1,930

240

18.1

5.5

1.2

1.2

2.5

0.5

2.1

2.3

2.3

39

45

43

3,310

4,090

3,800

1,770

2,550

2,260

300

20.4

5.5

1.3

1.2

2.5

0.5

2.2

2.4

2.3

42

49

46

3,980

4,970

4,490

2,040

3,040

2,560

400

23.2

5.5

1.3

1.3

2.5

0.5

2.3

2.5

2.4

44

52

49

4,870

5,930

5,420

2,410

3,460

2,950

500

26.3

5.5

1.3

1.3

2.5

 

2.3

2.6

2.5

50

53

50

5,800

6,960

6,380

2,630

3,800

3,210

500

26.3

5.5

1.4

1.4

2.5

0.5

2.4

2.6

2.5

48

56

52

6,030

7,250

6,640

2,860

4,080

3,640

630

30.2

5.5

1.4

 

2.5

 

2.5

2.7

 

53

60

 

7,640

9,970

 

3,540

6,180

 

800

34

5.5

1.4

 

2.5

 

2.6

2.9

 

57

65

 

9,450

12,080

 

4,190

7,160

 

1000

38.7

5.5

1.6

 

2.5

 

2.7

3

 

61

69

 

11530

14400

 

4950

7910

 

16mm2 to 800mm2 are normal compact round for single and multi core cable.
800mm2 and above are compact round segments for single core cable.
AWA:Aluminum Wire Armoured /DATA:Double Al.Tape Amoured/UnAr:Unarmoured
Only the galogen free cables shall be generally complied with IEC 61034 and 60754.
For the 1 core cables armoured with magnetic materials using in communication system ,
even specific strcuture is applied, the carrying capacity will be greatly reduced, so should be should be carefully selected.

12/20kV 3 Cores XLPE Cable

Construction Table (in accordance with IEC 60502-2, 61034 and 60754)

Nominal Croess-sectional Area

Approx. Outside diameter of Conductor

Thickness of the insulation (non.)

Thickness of Extruded Inner Covering

Diameter of Amour Wire (nom.)

Thickness of the PVC Outer Sheath (nom.)

Approx. Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluninum Conductor

GSWA

DSTA

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

mm2

mm

mm

mm

mm

mm

mm

kg/km

kg/km

35

6.9

5.5

1.5

1.5

2.5

0.5

2.6

2.9

2.8

53

61

58

3,170

6,190

4,570

2,520

5,530

3,920

50

8.1

5.5

1.6

1.6

2.5

0.5

2.7

3.0

2.9

56

64

61

3,690

6,870

5,180

2,800

5,980

4,290

70

9.8

5.5

1.6

1.6

2.5

0.5

2.8

3.1

3.0

60

68

65

4,530

7,940

6,110

3,240

6,650

4,820

95

11.4

5.5

1.7

1.7

2.5

0.5

2.9

3.2

3.1

64

72

69

5,520

9,150

7,230

3,730

7,370

5,440

120

12.8

5.5

1.8

1.8

3.2

0.5

3.0

3.4

3.2

67

77

72

6,480

11,310

8,310

4,200

9,040

6,040

150

14.2

5.5

1.8

1.8

3.2

0.5

3.1

3.5

3.3

70

80

76

7,510

12,630

9,430

4,700

9,820

6,620

185

15.8

5.5

1.9

1.9

3.2

0.5

3.2

3.6

3.4

74

84

80

8,810

14,190

10,870

5,300

10,680

7,360

240

18.1

5.5

2.0

2.1

3.2

0.8

3.4

3.8

3.7

81

92

88

11,050

17,000

14,370

6,390

12,340

9,710

300

20.4

5.5

2.1

2.1

3.2

0.8

3.6

3.9

3.8

86

97

93

13,210

19,630

16,690

7,350

13,770

10,830

400

23.2

5.5

2.2

2.2

3.2

0.8

3.8

4.2

4.1

92

104

100

16,140

23,280

20,000

8,660

15,810

12,520




















16mm2 to 800mm2 are normal compact round for single and multi core cable.
800mm2 and above are compact round segments for single core cable.
GSWA:Galvanized Wire Armoured /DSTA:Double Steel Tape Amoured/UnAr:Unarmoured
Only the galogen free cables shall be generally complied with IEC 61034 and 60754.

18/30kV 1 Cores XLPE Cable

Construction Table (in accordance with IEC 60502-2, 61034 and 60754)

Nominal
 Cross-sectional
 Area

Approx.
 Outside
 Diameter
 of
 Conductor

Thickness
 of
 Insulation

Thickness
 of Extruded
 Inner
 Covering

Diameter of
 Armour
 Wire
 (nom.)

Thichness of PVC Outer Sheath (nom.)

Approx.
 Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluminum
 Conductor

AWA

DSTA

AWA

DSTA

UnAr

AWA

DSTA

UnAr

GSWA

DSTA

UnAr

AWA

DSTA

UnAr

AWA

DSTA

mm2

mm

mm

mm

mm

mm

mm

Kg/km

Kg/km

50

8.1

8.0

1.8

1.8

3.15

0.5

3.1

3.4

3.3

72

78

77

5,210

10,360

7,160

4,310

9,470

6,270

70

9.8

8.0

1.8

1.8

3.15

0.5

3.2

3.5

3.4

76

85

81

6,110

11,500

8,170

4,830

10,210

6,880

95

11.4

8.0

1.9

1.9

3.15

0.5

3.3

3.7

3.5

79

90

85

7,110

12,960

9,390

5,330

11,170

7,600

120

12.8

8.0

2

2

3.15

0.8

3.4

3.8

3.7

83

93

90

8,250

14,270

11,620

5,970

12,000

9,050

150

14.2

8.0

2

2

3.15

0.8

3.5

3.9

3.8

86

97

93

9,340

15,590

12,830

6,530

12,780

10,020

185

15.8

8.0

2.1

2.1

3.15

0.8

3.6

4

3.9

90

101

97

10,740

17,330

14,430

7,230

13,820

10,920

240

18.1

8.0

2.2

2.2

3.15

0.8

3.8

4.2

4.1

97

107

104

13,120

20,200

17,110

8,460

15,540

12,450

300

20.4

8.0

2.3

2.3

3.15

0.8

3.9

4.3

4.2

102

112

109

15,350

22,860

19,580

9,490

17,000

13,720

400

23.2

8.0

2.4

2.5

3.15

0.8

4.2

4.6

4.5

108

121

116

18,440

26,940

23,200

10,970

19,470

15,720

16mm2 to 800mm2 are normal compact round for single and multi core cable.
800mm2 and above are compact and round segments for single core cable.
AWA:Aluminum Wire Armoured /DATA:Double Al.Tape Amoured/UnAr:Unarmoured
Only the halogen free cables shall be generally complied with IEC 61034 and 60454.
For the 1 core cables armoured with magnetic materials using in communication system ,
even specific strcuture is applied, the carrying capacity will be greatly reduced, so should be should be carefully selected.

18/30kV 3 Cores XLPE Cable

Construction Table (in accordance with IEC 60502-2, 61034 and 60754)

Nominal
 Cross-sectional
 Area

Approx.
Outside
 Diameter
 of
 Conductor

Thickness
 of
 Insulation

Thickness
 of Extruded
 Inner
 Covering

Diameter of
 Armour
 Wire
 (nom.)

Thichness of PVC Outer Sheath (nom.)

Approx.
 Overall Diameter

Approx. Weight of Cable

Copper Conductor

Aluminum
 Conductor

GSWA

DSTA

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

UnAr

GSWA

DSTA

mm2

mm

mm

mm

mm

mm

mm

Kg/km

Kg/km

50

8.1

8.0

1.2

1.2

2.0

0.5

1.9

2.2

2.1

34

41

37

1,440

2,140

1,720

1,140

1,840

1,380

70

9.8

8.0

1.2

1.2

2.0

0.5

2

2.2

2.1

36

43

40

4,720

2,440

2,160

1,300

2,010

1,740

95

11.4

8.0

1.2

1.2

2.0

0.5

2.1

2.3

2.2

38

44

42

2,040

2,800

2,510

1,450

2,220

1,920

120

12.8

8.0

1.2

1.2

2.0

0.5

2.1

2.3

2.3

40

46

44

2,360

3,130

2,850

2,030

2,470

2,100

150

14.2

8.0

1.3

1.3

2.5

0.5

2.1

2.4

2.3

41

49

46

2,670

3,670

3,200

1,750

2,750

2,270

185

15.8

8.0

1.3

1.3

2.5

0.5

2.2

2.5

2.4

43

51

47

3,110

4,150

3,660

1,950

2,990

2,500

240

18.1

8.0

1.3

1.3

2.5

0.5

2.3

2.5

2.4

46

54

50

3,820

4,910

4,380

2,280

3,370

2,840

300

20.4

8.0

1.4

1.4

2.5

0.5

2.4

2.6

2.5

48

56

53

4,510

5,680

5,120

2,580

3,750

3,190

400

23.2

8.0

1.4

1.4

2.5

0.5

2.5

2.7

2.6

51

59

56

5,440

6,670

6,090

2,970

4,210

3,620

500

26.3

8.0

1.5

1.5

2.5

0.5

2.5

2.8

2.7

55

63

59

6,600

8,050

7,340

3,430

4,880

4,170

630

30.2

8.0

1.6

 

2.5

 

2.7

2.9

 

60

66

 

8,300

9,150

 

4,200

5,360

 

800

34

8.0

1.6

 

2.5

 

2.8

3

 

64

70

 

10,150

11,100

 

4,890

6,190

 

1000

38.7

8.0

1.6

 

2.5

 

2.9

3.2

 

68

75

 

12,310

13,650

 

5,720

7,160

 

16mm2 to 800mm2 are normal compact round for single and multi core cable.
800mm2 and above are compact and round segments for single core cable.
GSWA:Galvanized Steel Wire Amoured/ DSTA:Double Steel Tape Amoured/ UnAr:Unaroured
Only the halogen free cables shall be generally complied with IEC 61034 and 60454.

If you are in need of aluminium/copper conductorxlpe power cable iec 60502, welcome to buy the quality and discount products with low price from our factory. Known as one of the leading manufacturers and suppliers, we must be your best choice. Check the price list and the quotation with us now.

Inquiry

Products
Overhead Conductor
Aerial Insulated Cable
0.6/1KV Power Cable
Up to 35 KV Power Cable
Equipment Cable
Concentric Cable
Special Cable
About Us
Company Profile
History
Management Philosophy
Company Certificate
Social Responsibility
Technology
Overhead Conductors
ower Cable
Wires and Cables for Electrical Equipment
Contact Us

Shijiawan industrial estate,Yanshi city,Henan,China

Tel: +86-371-5515-7231

sales1@htcable.cn

Copyright © Huatong Cable Inc All Rights Reserved.