Mv Medium Voltage ABC Cable Power Cable

Medium voltage Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.

Product Details

APPLICATION:
Medium voltage Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders to residential premises.
STANDARDS
Basic design to IEC 60502 / AS/NZS 3599-1 standards
CABLE CONSTRUCTION
Phase Conductor: Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen: Extruded semi-conductive layer.
insulation: XLPE.
insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
outer Sheath: HDPE.
Support Conductor: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel  wires in a right hand lay.
Construction Parameters
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines



Number of Cores
xNominal
Cross Section
Phase ConductorMessenger Suspension UnitContinuous
current
rating
at
300C
ambient
temp
StrandingNominal
Sectional
Area
Maximum
Conductor
Resistance
StrandingNominal
Sectional
Area
Breaking
Load
No.×mm²No.×mmmm²Ω/KmNo.×mmmm²KNA
3X50 + 1X2519/1.78500.6417/3.05060116
3X70 + 1X5019/.14700.4437/3.155062210
3X95+ 1X5019/2.52950.327/3.05060173
3X185+1X12037/2.521850.1647/4.67120150259
3X150 +1X5037/2.251500.2067/3.155062365
3X240 +1X5061/2.252400.1257/3.155062500


Other cross-sections can be offered upon request.
IEC 60502 19/33 kV ABC for Overhead Distribution Lines


Number of Cores
xNominal
Cross Section
Phase ConductorMessenger Suspension UnitContinuous
current
rating
at
300C
ambient
temp
StrandingNominal
Sectional
Area
Maximum
Conductor
Resistance
StrandingNominal
Sectional
Area
Breaking
Load
No.×mm²No.×mmmm²Ω/KmNo.×mmmm²KNA
3X50 + 1X5019/1.78500.6417/3.05060165
3X150+ 1X5037/2.251500.2067/3.05060315
3X185+1X7037/2.521850.1647/3.577091355
3X70 +1X5019/2.1470.4437/3.155062250
3X150 +1X5037/2.251500.2067/3.155062370


Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /HDPE Non-screened Cables


Number of Cores
xNominal
Cross Section
Phase ConductorMessenger
Suspension Unit
Nominal Sectional AreaBreaking
Load
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation
Screen
Thickness
of
Sheath
Stranding
No.×mm²mmmmmmmmNo.×mmmm²KN
3x356.93.40.81.27/4.7552.41370
3x508.13.40.81.27/4.7554.61530
3x709.73.40.81.27/4.7557.81790
3x9511.43.40.81.27/4.7561.32100
3x12012.83.40.81.219/3.5067.32540
3x15014.23.40.81.219/3.5070.12840
3x18515.73.40.81.219/3.5073.13190


Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /CWS/HDPE Screened Cables


Number of Cores
xNominal
Cross Section
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Copper Wire Screen
Stranding
Thickness
of
Sheath
Galvanized Steel Wire StrandingNominal Sectional AreaBreaking
Load
No.×mm²mmmmmmNo.×mmmmNo.×mmmm²KN
Light Duty Screen
3x356.93.40.825/0.851.87/2.0054.11820
3x356.93.40.825/0.851.819/2.0058.12130
3x508.13.40.825/0.851.819/2.0060.42300
3x709.73.40.825/0.851.819/2.0063.62570
3x9511.43.40.825/0.851.819/2.0067.02900
3x12012.83.40.825/0.851.819/2.0069.83190
3x15014.23.40.825/0.851.919/2.0073.03530
3x18515.73.40.825/0.851.919/2.0076.03890
Heavy Duty Screen
3x356.93.40.840/0.851.87/2.0054.12050
3x356.93.40.840/0.851.819/2.0058.12360
3x508.13.40.823/1.351.819/2.0062.42820
3x709.73.40.832/1.351.819/2.0065.63440
3x9511.43.40.839/1.351.819/2.0069.04030
3x12012.83.40.839/1.351.819/2.0071.84320
3x15014.23.40.839/1.351.919/2.0075.04670
3x18515.73.40.839/1.351.919/2.0078.05020


Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /HDPE Non-screened Cables

Number of Cores
xNominal
Cross Section
Phase ConductorMessenger
Suspension Unit
Nominal Sectional AreaBreaking
Load
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation
Screen
Thickness
of
Sheath
Stranding
No.×mm²mmmmmmmmNo.×mmmm²KN
3x356.95.50.81.27/4.7561.01780
3x508.15.50.81.27/4.7563.31970
3x709.75.50.81.27/4.7566.52260
3x9511.45.50.81.27/4.7569.92600
3x12012.85.50.81.219/3.5075.93070
3x15014.25.50.81.219/3.5078.73390
3x18515.75.50.81.219/3.5081.73760


Other cross-sections can be offered upon request.
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /CWS/HDPE Screened Cables

Number of Cores
xNominal
Cross Section
Diameter
of
Conductor
Thickness
of
Insulation
Thickness
of
Insulation Screen
Copper Wire
Screen Stranding
Thickness
of
Sheath
Galvanized
Steel Wire Stranding
Nominal Sectional
Area
Breaking
Load
No.×mm²mmmmmmNo.×mmmmNo.×mmmm²KN
Light Duty Screen
3x356.95.50.825/0.851.87/2.0062.72280
3x356.95.50.825/0.851.819/2.0066.72580
3x508.15.50.825/0.851.819/2.0069.02780
3x709.75.50.825/0.851.919/2.0072.63110
3x9511.45.50.825/0.851.919/2.0076.03460
3x12012.85.50.825/0.852.019/2.0079.23810
3x15014.25.51.025/0.852.019/2.0082.84230
3x18515.75.51.025/0.852.119/2.0086.24650
Heavy Duty Screen
3x356.95.50.840/0.851.87/2.0062.72510
3x356.95.50.840/0.851.819/2.0066.72810
3x508.15.50.823/1.351.819/2.0071.03300
3x709.75.50.832/1.351.919/2.0074.63970
3x9511.45.50.839/1.351.919/2.0078.04600
3x12012.85.50.839/1.352.019/2.0081.24950
3x15014.25.51.039/1.352.019/2.0084.85360
3x18515.75.51.039/1.352.119/2.0088.25790


Other cross-sections can be offered upon request.
Technical Data

Nominal
Cross Section
Continuous Current Rating
Still air1m/s wind2m/s wind
mm²AAA
35105145165
50125170200
70150215250
95180260300
120205300350
150230340395
185265390450


Packaging & Shipping

1) Packing length:100 to 1,000m reeled in carton drum
2) Outer packing: wooden case, carton box
3) Other packing requirement according to client's request.


Our Services

Advanced connectors & assembly cables machines and testing equipments.
Large production capacity, short delivery.
Prompt quotation for your inquiry.
More than 10 years experiences in cable and wire field.

OEM/ODM service available, help you on designing.

Strict QC checking before delivery.
Professional connector and cable manufacturer, with good quality and competitive price.
free samples are available for further evaluation and you are highly welcome to visit our factory anytime!!


If you are in need of mv medium voltage abc cable power cable, welcome to buy the quality and discount products with low price from our factory. Known as one of the leading manufacturers and suppliers, we must be your best choice. Check the price list and the quotation with us now.

Hot Tags: mv medium voltage abc cable power cable, factory, manufacturers, suppliers, quotation, price list, low price, buy discount
Related Products

Inquiry

Products
Overhead Conductor
Aerial Insulated Cable
0.6/1KV Power Cable
Up to 35 KV Power Cable
Equipment Cable
Concentric Cable
Special Cable
About Us
Company Profile
History
Management Philosophy
Company Certificate
Social Responsibility
Technology
Overhead Conductors
ower Cable
Wires and Cables for Electrical Equipment
Contact Us

Shijiawan industrial estate,Yanshi city,Henan,China

Tel: +86-371-5515-7231

sales1@htcable.cn

Copyright © Huatong Cable Inc All Rights Reserved.