Huatong Cable Inc

Product

Contact Us

Share
Bare Conductor AAAC

Bare Conductor AAAC

AAAC (All Aluminum Alloy Conductor) referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;

Chat Now

Product Details

1. Brief Introduction:
AAAC (All Aluminum Alloy Conductor) referred to have higher strength than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;
 
Having lower breaking loads than the latter, their use becomes particularly favourable when ice and win loadings are low. 
We can supply this Bare Conductor AAAC according to different recognized standards, such as BS EN50182, IEC61089, ASTM B399DIN 48, customer special specification also can be satisfied. 
 
2.  Applications of Bare Conductor AAAC:
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. Aluminum-alloy gives 6201-T81 gives AAAC higher resistance to corrosion than ACSR.
 

                                            ALUMINIUM ALLOY CONDUCTOR                    ASTM B399

Code Name

Area

Size&Stranding of ACSR with equal diameter

No. and diameter 

Overall diameter

Weight

Nominal breaking load

MAX .DC resistance at 20ºC

Nominal

Actual

AWG or MCM

Al/St


MCM

mm2



mm

mm

kg/km

kN

ohm/km

AKRON

30.58

15.48

6

6/1

7/1.68

5.04

42.7

4.92

0.3966

ALTON

48.69

24.71

4

6/1

7/2.12

6.35

68

7.84

0.3811

AMES

77.47

39.22

2

6/1

7/2.67

8.02

108

12.45

0.3671

AZUSA

123.3

62.38

1/0

6/1

7/3.37

10.11

172

18.97

0.3524

ANAHEIM

155.4

78.65

2/0

6/1

7/3.78

11.35

217

23.93

0.3448

AMHERST

195.7

99.22

3/0

6/1

7/4.25

12.75

273

30.18

0.3375

ALLIANCE

246.9

125.1

4/0

6/1

7/4.77

14.31

345

38.05

0.3306

BUTTE

312.8

158.6

266.8

26/7

19/3.26

16.3

437

48.76

0.3196

CANTON

394.5

199.9

366.4

26/7

19/3.66

18.3

551

58.91

0.3124

CAIRO

465.4

235.8

397.5

26/7

19/3.98

19.88

650

69.48

0.3071

DARIEN

559.5

283.5

477

26/7

19/4.36

21.79

781

83.52

0.3014

ELGIN

652.4

330.6

556.5

26/7

19/4.71

23.54

911

97.42

0.2966

FLINT

740.8

375.3

636

26/7

37/3.59

25.16

1035

108.21

0.2917

GREELY

927.2

469.8

795

26/7

37/4.02

28.14

1295

135.47

0.2846

 
  

Area

Stranding and wire diameter

Approx. overall diameter

Weight

Nominal Breaking Load

MAX .DC resistance at 20ºC

Nominal

Actual

AWGorMCM

(mm2)

(mm)

(mm)

(kg/km)

(kN)

(ohm/km)

6

13.30

7/1.554

4.67

37

4.22

2.5199

4

21.15

1/1.961

5.89

58

6.71

1.5824

2

33.63

7/2.474

7.42

93

10.68

0.9942

1/0

53.48

7/3.119

9.36

148

16.97

0.6256

2/0

67.42

7/3.503

10.51

186

20.52

0.4959

3/0

85.03

7/3.932

11.8

234

25.86

0.3936

4/0

107.23

7/4.417

13.26

296

32.63

0.3119

250

126.66

19/2.913

14.57

349

38.93

0.2642

300

152.1

19/3.193

15.97

419

46.77

0.2199

350

177.35

19/3.447

17.24

489

52.25

0.1887

400

202.71

19/3.686

18.43

559

59.74

0.1650

450

228

19/3.909

19.55

629

67.19

0.1467

500

253.35

19/4.120

20.60

698

74.64

0.1321

550

278.60

37/3.096

21.67

768

83.80

0.1202

600

303.80

37/3.233

22.63

838

91.38

0.1102

650

329.25

37/3.366

23.56

908

97.94

0.1016

700

354.55

37/3.493

24.45

978

102.20

0.0944

750

380.20

37/3.617

25.32

1049

109.60

0.0880

800

405.15

37/3.734

26.14

1117

116.80

0.0826

900

456.16

37/3.962

27.73

1258

131.50

0.0733

1000

506.71

37/4.176

29.23

1399

146.10

0.0660

1100

557

61/3.41

30.69

1537

162.16

0.0589

1200

608

61/3.56

32.04

1677

176.75

0.0541

1300

659

61/3.71

33.39

1816

191.95

0.0498

1400

709

61/3.85

34.65

1955

206.72

0.0463

1500

760

61/3.98

35.82

2095

220.90

0.0441

1600

811

61/4.12

37.08

2236

235.57

0.0405

1700

861

61/4.24

38.16

2374

250.72

0.0382

1800

912

61/4.36

39.28

2514

265.11

0.03693

1900

963

91/3.67

40.37

2655

277.10

0.03411

2000

1013

91/3.76

41.4

2793

292.41

0.03243

  

                                      ALUMINIUM ALLOY CONDUCTOR             BSEN50183

Code Name

Calculated Area

No. Of Wires

Diameter

Weight

Rated Strength

MAX .DC resistance at 20ºC

Wire

Cond.


mm2


mm

mm

kg/km

Kn

ohm/km

Box

18.8

7

1.85

5.55

51.4

5.55

1.748

Acacia

23.8

7

2.08

6.24

64.9

7.02

1.3828

Almond

30.1

7

2.34

7.02

82.2

8.88

1.0926

Cedar

35.5

7

2.54

7.62

96.8

10.46

0.9273

Deodar

42.2

7

2.77

8.31

115.2

12.44

0.7797

Fir

47.8

7

2.95

8.85

130.6

14.11

0.6875

Hazel

59.9

7

3.3

9.9

163.4

17.66

0.5494

Pine

71.6

7

3.61

10.8

195.6

21.14

0.4591

Holly

84.1

7

3.91

11.7

229.5

24.79

0.3913

Willow

89.7

7

4.04

12.1

245

26.47

0.3665

Oak

118.9

7

4.65

14

324.5

35.07

0.2767

Mulberry

150.9

19

3.18

15.9

414.3

44.52

0.2192

Ash

180.7

19

3.48

17.4

496.1

53.31

0.183

Elm

211

19

3.76

18.8

579.2

62.24

0.1568

Poplar

239.4

37

2.87

20.1

659.4

70.61

0.1387

Sycamore

303.2

37

3.23

22.6

835.2

89.4

0.1095

Upas

362.1

37

3.53

24.7

997.5

106.82

0.0917

Yew

479

37

4.06

28.4

1319.6

141.31

0.0693

Totara

498.1

37

4.14

29

1372.1

146.93

0.0666

Rubus

586.9

61

3.5

31.5

1622

173.13

0.0567

Sorbus

659.4

61

3.71

33.4

1822.5

194.53

0.0505

Araucaria

821.1

61

4.14

37.3

2269.4

242.24

0.0406

Redwood

996.2

61

4.56

41

2753.2

293.88

0.0334

 

ALUMINIUM ALLOY CONDUCTOR                 BS 3242

Code Name

Calculated Area

No. Of Wires

Diameter

Weight

Rated Strength

MAX .DC resistance at 20ºC

Wire

Cond.


mm2


mm

mm

kg/km

Kn

ohm/km

Box

15

7/1.85

18.82

5.55

51

537

1.7495

Acacia

20

7/2.08

23.79

6.24

65

680

1.384

Almond

25

7/2.34

30.1

7.02

82

861

1.0934

Cedar

30

7/2.54

35.47

7.62

97

1014

0.9281

-

35

7/2.77

42.18

8.31

115

1205

0.7804

Fir

40

7/2.95

47.87

8.85

131

1367

0.688

Hazel

50

7/3.30

59.87

9.9

164

1711

0.5498

Pine

60

7/3.61

71.65

10.83

196

2048

0.4594

-

70

7/3.91

84.05

11.73

230

2402

0.3917

Willow

75

7/4.04

89.73

12.12

245

2565

0.3669

-

80

7/4.19

96.52

12.57

264

2758

0.3441

-

90

7/4.44

108

13.32

298

3112

0.3023

Oak

100

7/4.65

118.9

13.95

325

3398

0.2769

-

100

19/2.82

118.7

14.1

326

3393

0.2787

Mulbery

125

19/3.18

150.9

15.9

415

4312

0.2192

Ash

150

19/3.48

180.7

17.4

497

5164

0.1831

Elm

175

19/3.76

211

18.8

580

6030

0.1568

Poplar

200

37/2.87

239.4

20.09

659

8841

0.1385

-

225

37/3.05

270.3

21.35

744

7724

0.1227

Sycamore

250

37/3.22

303.2

22.54

835

8664

0.1093

Upas

300

37/3.53

362.1

24.71

997

10350

0.09156

Walnut

350

37/3.81

421.8

26.67

1162

12053

0.0786

Yew

400

37/4.06

479

28.42

1319

13685

0.06921

Totara

425

37/4.14

498.1

28.98

1372

14233

0.06656

Rubus

500

61/3.50

586.9

31.5

1620

16771

0.05662

Araucaria

700

61/4.14

821.1

37.26

2266

23450

0.04047

 3. 
(1).What is the difference between ACSR, AAC and AAAC Conductors?
The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel.
 
The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium.
 

Packaging & Shipping

Bare Conductor AAAC


1) Packing length:100 to 1,000m reeled in carton drum 
2) Outer packing: wooden case, carton box
3) Other packing requirement according to client's request.


Our Services

Bare Conductor AAAC


Advanced connectors & assembly cables machines and testing equipments.
Large production capacity, short delivery.
Prompt quotation for your inquiry.
More than 10 years experiences in cable and wire field.

OEM/ODM service available, help you on designing.

Strict QC checking before delivery.
Professional connector and cable manufacturer, with good quality and competitive price.
free samples are available for further evaluation and you are highly welcome to visit our factory anytime!!


If you are in need of bare conductor aaac, welcome to buy the quality and discount products with low price from our factory. Known as one of the leading manufacturers and suppliers, we must be your best choice. Check the price list and the quotation with us now.

Hot Tags: bare conductor aaac, factory, manufacturers, suppliers, quotation, price list, low price, buy discount
Related Products

Inquiry

Products
Overhead Conductor
Aerial Insulated Cable
0.6/1KV Power Cable
Up to 35 KV Power Cable
Equipment Cable
Concentric Cable
Special Cable
About Us
Company Profile
History
Management Philosophy
Company Certificate
Social Responsibility
Technology
Overhead Conductors
ower Cable
Wires and Cables for Electrical Equipment
Contact Us

Shijiawan industrial estate,Yanshi city,Henan,China

Tel: +86-371-5515-7231

sales1@htcable.cn

Copyright © Huatong Cable Inc All Rights Reserved.